High Voltage Probes
The PPE series of probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are five fixedattenuation probes covering a range from 2 kV to 20 kV, and one switchable probe providing ÷10/÷100 attenuation for voltage inputs up to 1.2 kV.
New technology which utilizes hybrid circuitry (and switch reading for probes with switchable gain/attenuation) minimizes ringing and overshoot to provide a precise response.
All fixed-attenuation, standard probes automatically rescale any LeCroy 9300C or LC series oscilloscope for the appropriate attenuation factor of the probe.
Supplied with the probe :
1) Probe Kit : trimming tool, ground lead, rigid tip, IC insulator, BNC adaptor, tip insulator, spring hook, red crocodile clip, 4 mm safety adaptor, safety ground lead, green/yellow crocodile clip.
2) Probe Kit : trimming tool, ground lead with a crocodile clip.
The PPE series is compatible with all LeCroy oscilloscopes.
Accessory Kit for PPE series :
PK103 (except PPE20KV)
PK104 (PPE20KV only)
High-Voltage Probes Selection Guide
| Types | Bandwidth MHz | Input R Ohm | Input C pF | Attenuation | Maximum Voltage | Probe Ring | Cable Length |
|---|---|---|---|---|---|---|---|
| PPE1.2KV1 | 400 | 50M | <6 | 10:1/100:1 | 600 V/1.2 kV | No | 2m |
| PPE2kV1 | 400 | 50M | <6 | 100:1 | 2kV | Yes | 2m |
| PPE4kV1 | 400 | 50M | <6 | 100:1 | 4kV | Yes | 2m |
| PPE5kV1 | 400 | 50M | <6 | 100:1 | 5kV | Yes | 2m |
| PPE6kV1 | 400 | 50M | <6 | 1000:1 | 6kV | Yes | 2m |
| PPE20kV2 | 100 | 100M | <3 | 1000:1 | 20kV 40kV Peak |
Yes | 3m |
For more information about High Voltage Probes contact us